SERVICEMANUALRGV12100 / 13100TModelsPUB-GS1328Rev. 09/01GENERATORS

Page 2 - CONTENTS

−−7−−4-2-2 ROTORThe rotor consists of a laminated silicon steelsheet core and a field coil which is woundover the core.DC current in the field coil ma

Page 3

−−8−−4-2-5 A.V.R (AUTOMATIC VOLTAGE REGULATOR)(RGV12100 only)The automatic voltage regulator employs anelectronic circuit to automatically regulatevol

Page 4 - 1. SPECIFICATIONS

−−9−−4-2-7 IDLE CONTROL UNIT (RGV12100 only)The idle control unit 11 releases throttlevalve when the applied load current exceeds0.04A.The two output

Page 5 - 2. PERFORMANCE CURVES

−−10−−Model Specification No-fuse Breaker Object of ProtectionRGV12100 60Hz-120V/240V 39A Total output amperageRGV13100T 60Hz-120V/208V 24A Total outp

Page 6

−−11−−4-2-11 AC ReceptacleAC receptacles are used for taking AC output power from the generator. A total of 4 kinds of receptacle, each varying in rat

Page 7 - (RGV12100)

−−12−− Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take acurrent exceeding the specified amperage. Be sure tha

Page 8 - SERIAL NUMBER

−−13−−GFCI RECEPTACLEAfter starting the engine, check the GFCI for proper functioning by the following test procedure. Push blue TEST button, The red

Page 9 - 4. CONSTRUCTION AND FUNCTION

−−14−−MAIN POWER LINETRANSFER SWITCHUTILITY HIGH LINECONNECTING BOX240VRECEPTACLEUtility high lineMeter boxGeneratorHouse circuit breakerXWYX(X)(Y)(G)

Page 10 - 1 2 31 2 31 2 3

−−15−−(c) Operating the generator. Turn the house AC breaker off before starting the generator. Start the generator and warm it up. Turn the house AC

Page 11

−−16−−SINGLE-PHASE OUTPUTWGYXZ Three phase application (208V)Insert the plug into the receptacle X, Y andZ.Generator rated output : 10000VAAC (THREE P

Page 12

CONTENTSSection Title Page1. SPEC

Page 13

−−17−−4-3 DESCRIPTION of GENERATOR OPERATION4-3-1 PRIMARY EXCITING ACTION(RGV12100)When the generator is started, the perma-nent magnet on the engine

Page 14 - AC 120V / 240V

−−18−−4-3-4 THE ADVANTAGES OF CURRENT TRANSFORMER CONTROL (RGV13100T)With AVR control, control is effected according to variations in output voltage.W

Page 15 - GFCI (Ground Fault Circuit

−−19−−5. SAFETY PRECAUTIONS1. Use extreme caution near fuel. A constant danger of explosion or fire exists.Do not fill the fuel tank while the engine

Page 16

−−20−−6. RANGE OF APPLICATIONSGenerally, the power rating of an electrical appliance indicates the amount of work that can bedone by it. The electric

Page 17

−−21−−NOTE 2 : Motor-driven appliances mentioned in lets (3) and (4) vary in their required motor startingpower depending on the kind of motor and sta

Page 18

−−22−−NOTES : Wiring between generator and electrical appliances1. Allowable current of cable Use a cable with an allowable current that is higher tha

Page 19 - SINGLE PHASE AC120V

−−23−−FOR AC7. MEASURING PROCEDURES(2) AMMETERAC ammeter is necessary. An AC ammeter with a range that can bechanged according to the current ratingof

Page 20

−−24−−(4) CIRCUIT TESTERUsed for measuring resistance, etc.(5) MEAGER TESTERUsed for measuring generator insulationresistance.Select one with testing

Page 21

−−25−−7-3MEASURING INSULATION RESISTANCEUse a megger tester to check the insulationresistance. Connect a megger tester to oneof receptacle output term

Page 22 - 5. SAFETY PRECAUTIONS

−−26−−●ROTORMeasure the resistance between the slip ringand the core.●CONTROL PANELMeasure the insulation resistance betweenthe live parts and the gro

Page 24

−−27−−8. CHECKING FUNCTIONAL MEMBERSPILOT LAMP8-2 AC RECEPTACLESUsing a circuit tester, check continuitybetween the two terminals at the rear of theAC

Page 25 - Resistance

−−28−−Model Hz/VoltageStator coilRed-White Black-Blue Black-RedWhite-Light greenBlack-WhiteRGV12100 60/120/2400.11Ω 0.11Ω------------0.37Ω------------

Page 26 - 7. MEASURING PROCEDURES

−−29−−8-5 ROTOR ASSEMBLY1) Field coilRemove the brush holder and measure resistance between the slip rings.NOTE : If the circuit tester is not suffici

Page 27

−−30−−8-7 BRUSHThe brushes must be smooth where theycontact the slip rings. If not, polish smooththe brushes with sandpaper. A brush that isnot smooth

Page 28

−−31−−* Checking table for analogue circuit tester. Analogue circuit testerApply black-needle of the circuit testerYellowBlack 11White 22Light green 3

Page 29

−−32−−Tester (-)Tester( )Pin No.11 22 33 44 55 66 77 88 99 !!00 !!11 !!22 !!3311-------∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞22∞-------∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞ ∞33∞18.4M-

Page 30 - PILOT LAMP

−−33−−8-12 DIODE UNIT (RGV13100T only)Check the resistance between five wires ofDIODE UNIT with circuit tester.Diode unitApply black 〇-needle of the c

Page 31

−−34−−9. DISASSEMBLY AND ASSEMBLY9-1 PREPARATION and PRECAUTIONS1) Be sure to memorize the location of individual parts when disassembling the generat

Page 32 - SANDPAPER

−−35−−9-3 COMPONENT PARTSFor disassembling and assembling, the following illustrations show the major component partsand their configuration for (1) G

Page 33 - Terminal number

−−36−−(1) Generator assembly11.8-13.7Nm120-140Kg-cm11.8-13.7Nm120-140Kg-cm22.5-24.5Nm230-250Kg-cmROTORSTATORBEARINGTHROUGH BOLTREAR COVERGENERATORBASE

Page 34

−−1−−1. SPECIFICATIONSModel RGV12100AlternatorTypeRated voltageBrush, Self-exciting, 2-pole, Single phase611 mm (752 mm *1)Rated frequency 60Hz771 mm

Page 35

−−37−−(2-1) Control Box (RGV12100)CONTROL BOXPLATENO-FUSEBREAKERAC RECEPTACLECONNECTORCAPA.V.R.(AUTOMATICVOLTAGEREGULATOR)IDLE CONTROLUNITECU (P4)EART

Page 36 - Light green

(2-2) Control Box (RGV13100T)CURRENT TRANSFORMERCONTROL BOXGROMETNO-FUSE BREAKERAC RECEPTACLEPILOT LAMPSTARTER SWITCHOIL PRESSURE WARNING LAMPGROMMETC

Page 37 - MOUNT RUBBER

−−39−−(3) Fuel TankFUEL GAUGEFUEL TANK CAPFUEL TANKFILTERPACKINGCUPHOSE CLAMPHOSECLAMPRUBBERPIPE (120 mm)RUBBERPIPE (630 mm)PURSELOCKFUEL FILTERFRANGE

Page 38 - Fig. 9-3

−−40−−9-4-1 FRONT COVERAttach the front cover to the engine mainbearing cover. Match the faucet joint andtighten the bolts.FRONT COVERBOLTSPRING WASHE

Page 39 - (1) Generator assembly

−−41−−Fig. 9-89-4-3 STATOR(1) Put the stator in the rear cover setting thefour grooves on the side of stator withthread holes of the rear cover.Tighte

Page 40 - (2-1) Control Box (RGV12100)

−−42−−9-5 REAR COVER(1) Put the rear cover with stator and statorcover over the rotor.Pull wires out from the rear cover.NOTE : Be careful not to give

Page 41 - (2-2) Control Box (RGV13100T)

−−43−−NOTE : When tightening the nuts, slightly lift thealternator assembly so that the weight isnot applied to the mount rubbers.(7) Fasten the earth

Page 42 - (3) Fuel Tank

10. TROUBLESHOOTING10-1 No AC output* Checking the exciting coil for resistance. (RGV12100) (Refer to 8-6.)If insulation is NG, replace exciting coil

Page 43 - SPRING WASHER

−−45−−10-4 Engine dose not run.Symptom Possible causes Remedy1. Electric starterdose not operate1) The key switch (or remoteswitch) is turned to "

Page 44 - STATOR COVER

5324(AC output)(AVR)1CONTROL BOXFuel cutIgnition coilAuto choke(Bimetal)ElectricstarterOil pressureswitchRegulatorMagneticswitchChargecoilExcitingcoil

Page 45 - Fig. 9-11

−−2−−2. PERFORMANCE CURVESHz(Hz)(V)(125)63250(120)240(115)230(110)2206261600 1/2 4/4Load Rated240V/120VRGV12100RGV13100THz(Hz)(V)632302202102006261600

Page 46 - EARTH CABLE

−−47−−(RGV13100T)CONTROL BOX1Fuel cutIgnition coilElectricstarterOil pressureswitchRegulatorMagneticswitchOil pressurewarning lamp(Red)ChargecoilElect

Page 47 - 10. TROUBLESHOOTING

PRINTED IN THE USA© Copyright 2001 Robin America, Inc.940 Lively Blvd.  Wood Dale, IL 60191  Phone: 630-350-8200  Fax: 630-350-8212e-mail: sales@r

Page 48 - 10-4 Engine dose not run

−−3−−3. GENERAL DESCRIPTION OF GENERATORSPARK PLUG CAPFUEL COCKBATTERYTANK CAPSPARK PLUGCAPOIL FILLER CAPMUFFLERCONNECTORFOR REMOTECONTROL(RGV12100 on

Page 49 - 11. WIRING DIAGRAM

−−4−−CONTROL PANEL(RGV12100)KEY SWITCHOIL PURESSUREWARNING LAMP0240110120220 IDLE CONTROLSWITCHVOLTMETERPILOT LAMP HOUR METERNO-FUSE BREAKERAC RECEPTA

Page 50 - (RGV13100T)

SERIAL NUMBERstamped label−−5−−SERIAL NUMBERSerial number is stamped on the label stuck on the end cover.NOTE : Always specify serial number when inqu

Page 51 - PRINTED IN THE USA

−−6−−4. CONSTRUCTION AND FUNCTION4-1 CONSTRUCTIONMOUNT RUBBER BALL BEARING TROUGH BOLTFRONT COVERREAR COVER ROTOR COMPLETESTATOR COMPLETESTATOR BOLTEN

Modèles reliés RGV13000T

Commentaires sur ces manuels

Pas de commentaire